Skip to product information

Leadleds Modbus TCP Communication Sign Outdoor LED Display Solutions

SKU: LLDP5-64384RGB-O
$1,910.00
Communicate way: WiFi/LAN
Product subtotal: $1,910.00

📦⏱Order Hand Time:7 ~ 10 business days, the shipping time is estimated at 3~ 7 days to arrive at your door.

  • Built to Last, Serve for Life

    Warranty: 1-year parts replacement | Lifetime Support | Ongoing Maintenance

  • Trusted in the U.S.

    Reliable LED Solutions for Your Business Success.

  • A Team with a Goal

    Real people making great products

Leadleds Modbus TCP Communication Sign Outdoor LED Display Solutions
Regular price $1,910.00
Regular price Sale price $1,910.00 (-0%)
Communicate way: WiFi/LAN
High-brightness outdoor display
Leadleds Modbus TCP Communication Sign Outdoor LED Display Solutions
$1,910.00
Your cart
Variant Variant total Quantity Price Variant total
High-brightness outdoor display
WiFi/LANLLDP5-64384RGB-O
WiFi/LANLLDP5-64384RGB-O
$1,910.00/ea
$0.00
$1,910.00/ea $0.00
Waterproof LED outdoor sign
TCP/IP with SDKLLDP5-SD64384RGB-O
TCP/IP with SDKLLDP5-SD64384RGB-O
$1,910.00/ea
$0.00
$1,910.00/ea $0.00
Commercial outdoor LED sign
Modbus TCP with ProtocolLLDP5-MD64384RGB-O
Modbus TCP with ProtocolLLDP5-MD64384RGB-O
$1,910.00/ea
$0.00
$1,910.00/ea $0.00

View cart
0

Total items

$0.00

Product subtotal

Taxes included. Discounts and shipping calculated at checkout.
View cart

Experience efficient communication and streamlined operations with Leadleds Modbus TCP Communication Sign. With the MODBUS protocol, easily connect and control a range of devices within your network. Enhance your productivity and efficiency with this premium outdoor LED display solution.

Brand Name: Leadleds
Type: single-sided outdoor Industrial LED Sign
Usage: outdoor waterproof
Display area size: Width 75.6 inches  × Height 12.6 inches (1,920 × 320mm)

Frame size: Width 78.3 inches  × Height 15.3 inches (1,988 × 388mm)
Pitch: 5mm
Pixel: 384 × 64, 3-in-1 full-color display, total of 24,576 dots display your messages
Display capability: Video/image/text/neon/graphic/animation/etc
Comms: Program by phone or ethernet, support iOS or Android, Windows
View distance: 5~80 meters 
Power by AC plug.

Effects :
Full-color display, highly attractive when this smart LED sign displays the letters, video, and pictures
Multiple scrolling message effects for you to apply to your ads, including flashing, static, moving to the left, moving to the right, and so on.

Store messages: this digital signage display can stock your messages and play at your appointed time
Energy-saving: Energy efficient, supports auto turn ON/OFF according to your setting.

Support Clock Function
Software supporting OS: Windows 7 & 8 &10, Windows Vista, Window XP / 98,/ 2000
Temperature Range: Storage-40° C to +60°C,  working -35°C to +55°C

What you'll receive:
Industrial LED sign for outdoor use
AC Plug
Mounting Hardware
Software and Manual.

You can receive the MODBUS protocol or SDK.

The MODBUS protocol allows simple communication within a variety of network architectures. Every device (PLC, HMI, control panel, driver, motion control, input/output device) can use the MODBUS protocol to initiate remote operations.

Modbus RTU Data frame structure
The instructions in the RTU protocol are composed of five parts: function code (one byte), starting address (two bytes), address code (one byte), data (N bytes), check code (two bytes), in which the data is composed of data length (two bytes, indicating the number of registers, assuming the content is M) and data body (M multiplied by two bytes).

Take 01 06 00 00 00 1F C8 02 for example

01  Address 01

06  Write Register

00 00  Register 0 corresponds to variable 0

00 1F  The value 31 is displayed

C8 02   Modbus CRC verification code

 

Modbus TCP data frame structure
Modbus TCP adds MBAP packet header to Modbus RTU. Since TCP is a service based on a reliable connection, there is no CRC check in Modbus TCP. All Modbus TCPADU sends and receives TCP transmission control protocols. The Modbus TCP/IP server usually uses port 502 as the port for receiving packets.

Take 00 01 00 00 00 06 01 06 00 00 00 00 00 1F for example

01  Address 01

06  Write Register

00 00  Register 0 corresponds to variable 0

00 1F  The value 31 is displayed

Modbus TCP The network protocol is not verified.

The modbus.ini file also supports text display by modifying the parameter configuration. The following is a description of the displayed text configuration parameters.

parameter name

Type

default

describe

MaxVarNo

int

1

The value ranges from 1 to 100

UnitType

int

1

Unit type: 0: units are not displayed. 1: displays the original unit. 2: Display replacement units, currently only ug/m3 can be replaced, need to use the font file "symbol.lmf"

Timeout

int

200

The Modbus protocol read timeout is expressed in milliseconds. The stable running of the current test cannot be less than 200ms

Interval

int

5000

Total cycle interval, in milliseconds

DispTypeNum

int

1

A maximum of 16 types can be displayed

AreaNum

int

4

The value can be a maximum of 32

1

string

0,1,leisure,0,255,0

Separated by commas, the first two are range values (close the interval, can be decimal), the third is the text to be displayed (not more than 32 bytes), if it is @@, it means that the original value is displayed, the following three are color RGB values, the whole line does not exceed 128 bytes

[1]

int

 

Variable number

DeviceAddr

int

1

Modbus device address

DataAddr

int

0

Data register address

DataLen

int

2

The value can be 1 or 2. 2 indicates that two values and four bytes are read at a time

Signed

int

0

Unsigned, 0. Unsigned number, 1. Signed number, 2. The highest digit is the sign 1 minus 0 plus.

Offset

int

0

Record the deviation between the data stored at the address and the actual value. The default value is 0, which takes precedence over the operator calculation

Sobel

int

1

Operator, multiply the read data by this operator to obtain the data to be displayed. The default is 1

Unit

string

ug/m3

The unit to be displayed is valid when UnitType=1/2. The maximum length is 10

Format

string

%d

Standard format string in the C language. The default is %d and the maximum length is 10

FillSpaceNum

int

0

The number of Spaces that need to be filled between data and units when displayed. The default value is 0

ExistDecimal

int

1

Whether there is a decimal, 1 exists, 0 does not exist. The default value is 0

DispTypeNo

int

1

The current value displays the display type number corresponding to "DispTypeNum". The value is "1" to "DISPtypenum"

Function

int

1

Variable function, 0. Display variable, 1. Select broadcast program, 2. Set brightness, default is 0

 

Recently viewed products

Related products