Leadleds Modbus TCP Communication Sign Outdoor LED Display Solutions
Couldn't load pickup availability
📦⏱Order Hand Time:7 ~ 10 business days, the shipping time is estimated at 3~ 7 days to arrive at your door.

|
0
Total items |
$0.00
Taxes included. Discounts and shipping calculated at checkout.
Product subtotal |
Experience efficient communication and streamlined operations with Leadleds Modbus TCP Communication Sign. With the MODBUS protocol, easily connect and control a range of devices within your network. Enhance your productivity and efficiency with this premium outdoor LED display solution.
Brand Name: Leadleds
Type: single-sided outdoor Industrial LED Sign
Usage: outdoor waterproof
Display area size: Width 75.6 inches × Height 12.6 inches (1,920 × 320mm)
Frame size: Width 78.3 inches × Height 15.3 inches (1,988 × 388mm)
Pitch: 5mm
Pixel: 384 × 64, 3-in-1 full-color display, total of 24,576 dots display your messages
Display capability: Video/image/text/neon/graphic/animation/etc
Comms: Program by phone or ethernet, support iOS or Android, Windows
View distance: 5~80 meters
Power by AC plug.
Effects :
Full-color display, highly attractive when this smart LED sign displays the letters, video, and pictures
Multiple scrolling message effects for you to apply to your ads, including flashing, static, moving to the left, moving to the right, and so on.
Store messages: this digital signage display can stock your messages and play at your appointed time
Energy-saving: Energy efficient, supports auto turn ON/OFF according to your setting.
Support Clock Function
Software supporting OS: Windows 7 & 8 &10, Windows Vista, Window XP / 98,/ 2000
Temperature Range: Storage-40° C to +60°C, working -35°C to +55°C
What you'll receive:
Industrial LED sign for outdoor use
AC Plug
Mounting Hardware
Software and Manual.
You can receive the MODBUS protocol or SDK.
The MODBUS protocol allows simple communication within a variety of network architectures. Every device (PLC, HMI, control panel, driver, motion control, input/output device) can use the MODBUS protocol to initiate remote operations.
Modbus RTU Data frame structure
The instructions in the RTU protocol are composed of five parts: function code (one byte), starting address (two bytes), address code (one byte), data (N bytes), check code (two bytes), in which the data is composed of data length (two bytes, indicating the number of registers, assuming the content is M) and data body (M multiplied by two bytes).
Take 01 06 00 00 00 1F C8 02 for example
01 Address 01
06 Write Register
00 00 Register 0 corresponds to variable 0
00 1F The value 31 is displayed
C8 02 Modbus CRC verification code
Modbus TCP data frame structure
Modbus TCP adds MBAP packet header to Modbus RTU. Since TCP is a service based on a reliable connection, there is no CRC check in Modbus TCP. All Modbus TCPADU sends and receives TCP transmission control protocols. The Modbus TCP/IP server usually uses port 502 as the port for receiving packets.
Take 00 01 00 00 00 06 01 06 00 00 00 00 00 1F for example
01 Address 01
06 Write Register
00 00 Register 0 corresponds to variable 0
00 1F The value 31 is displayed
Modbus TCP The network protocol is not verified.
The modbus.ini file also supports text display by modifying the parameter configuration. The following is a description of the displayed text configuration parameters.